I wanted to test the DPM fix for dCache to DPM file transfers. Greig had been doing some transfers from Edinburgh's dCache into Glasgow's DPM when the head node (se2-gla) had its dteam only pool writable. He noticed a significant failure rate, so I wondered if setting the TCP_NODELAY option had badly affected performance.

Testing to se2-gla

Tested using 10 file FTS transfer from Edinburgh's DPM.

File:Ed2gla se2 nodelay set then unset.png

Load is going very high on the machine, particularly CPU usage in latter half of transfer (as soon as first transfers have completed?). When NODELAY was unset 5 files failed to transfer (50%), when it was set 3 files failed to transfer (30%). Failures were in SRM layer, e.g., failing to do 'setDone' on target SRM.

When the NODELAY option was set there was some evidence of high Rcvd-Q values internal to DPM:

tcp   480771      0 se2-gla.scotgrid.ac.u:20000 dpm.epcc.ed.ac.uk:50004     ESTABLISHED
tcp   237686      0 se2-gla.scotgrid.ac.u:20001 dpm.epcc.ed.ac.uk:50005     ESTABLISHED
tcp   485298      0 se2-gla.scotgrid.ac.u:20001 dpm.epcc.ed.ac.uk:50006     ESTABLISHED
tcp   480771      0 se2-gla.scotgrid.ac.u:20001 dpm.epcc.ed.ac.uk:50007     ESTABLISHED
tcp   237703      0 se2-gla.scotgrid.ac.u:20000 dpm.epcc.ed.ac.uk:50000     ESTABLISHED
tcp   488235      0 se2-gla.scotgrid.ac.u:20000 dpm.epcc.ed.ac.uk:50001     ESTABLISHED
tcp   480767      0 se2-gla.scotgrid.ac.u:20000 dpm.epcc.ed.ac.uk:50002     ESTABLISHED
tcp   488054      0 se2-gla.scotgrid.ac.u:20000 dpm.epcc.ed.ac.uk:50003     ESTABLISHED
tcp   480784      0 se2-gla.scotgrid.ac.u:20001 dpm.epcc.ed.ac.uk:50008     ESTABLISHED
tcp   485294      0 se2-gla.scotgrid.ac.u:20001 dpm.epcc.ed.ac.uk:50009     ESTABLISHED

Confirms result that DPM daemons seem to fail to communicate properly under high load.

se2 has a single IDE disk, but I did check that DMA is on.

Testing to pool1-gla

Set se2 and pool2 pools to RDONLY, to force transfers onto pool1 (which has large fibre channel disk arrays). Repeated test.

File:Ed2gla pool1 nodelay set then unset.png

Machine performs pretty much identically in both cases. None of the files fail to transfer, rate is ~180Mb/s.

I'm thinking that having the DPM head node as a disk pool is very bad for DPM!

Conclusion

export RFIO_TCP_NODELAY=yes seems to be OK, but I'm concerned as to why transferring into se2 has become so unreliable. This was definitely not observed before Xmas.